IM1000-24
|
 |
| 1000 Watt 24V Inverter |
|
|
The perfect inverter to run the comforts of home when on long and demanding road trips. |
|
|
Efficient 24V Power Conversion The use of a 24V system allows more efficient production of power due to the reduced current. |
Peak Power Technology Heavy duty MOSFET transistors and a high output transformer allow the inverter to power maximum loads from start up. |
Superior Noise Free Filtering All Projecta inverters have EMC filtering and large electrolytic capacitors for smoother power delivery so your TV, radio, DVD, computers, etc, run as though they are on mains power. |
Twin 240V Power Outlets Any combination of sockets can be used, provided the combined load does not exceed the inverter's rating. |
Low Battery Voltage Protection To protect your battery from permanent damage caused by a deep discharge, the IM1000-24 has a low battery warning buzzer and shut off. |
Thermostatically Controlled Cooling Fan A built in cooling fan ensures that the inverter continues to provide reliable power for longer periods when under heavy loads. |
Internally Bonded Earth System All Projecta inverters have an internally bonded earth system. This ensures that in the event of a 240V appliance failing, the inverter will immediately shut down, preventing any chance of electrocution. |
Mounting Brackets Allows the inverter to be easily mounted. |
|
| PART NO. |
IM1000-24 |
| INPUT |
24V DC, 60A Max |
| OUTPUT |
230/240V AC 50Hz (Modified Sine Wave) |
| OUTPUT POWER |
1000W Continuous (2000W Peak) |
| IDEAL BATTERY SIZE |
40-130Ah |
| MINIMUM BATTERY SIZE |
40Ah, 350CCA
|
| RUN TIME WITH 1000W ON 40Ah BATTERY |
15 min |
| RUN TIME WITH 100W GLOBE ON 40Ah BATTERY |
6 hours
|
| APPROVALS |
Electrical Safety, EMC |
| IWK3 |
3m, 32mm2 (2 B&S) wiring kit |
| IWK4 |
6m, 49mm2 (0 B&S) wiring kit |
| IFB-100 |
Fuse box with 100A ANL fuse |
| IF-100 |
100A ANL fuse |
|
|

|
IM2000-24
|
 |
| 2000 Watt 24V Inverter |
|
|
Capable of running multiple appliances such as TVs and DVDs on vehicles where 240V power is a must. |
|
|
Efficient 24V Power Conversion The use of a 24V system allows more efficient production of power due to the reduced current. |
Peak Power Technology Heavy duty MOSFET transistors and a high output transformer allow the inverter to power maximum loads from start up. |
Superior Noise Free Filtering All Projecta inverters have EMC filtering and large electrolytic capacitors for smoother power delivery so your TV, radio, DVD, computers, etc, run as though they are on mains power. |
Twin 240V Power Outlets Any combination of sockets can be used, provided the combined load does not exceed the inverter's rating. |
Low Battery Voltage Protection To protect your battery from permanent damage caused by a deep discharge, the IM2000-24 has a low battery warning buzzer and shut off. |
Thermostatically Controlled Cooling Fan A built in cooling fan ensures that the inverter continues to provide reliable power for longer periods when under heavy loads. |
Internally Bonded Earth System All Projecta inverters have an internally bonded earth system. This ensures that in the event of a 240V appliance failing, the inverter will immediately shut down, preventing any chance of electrocution. |
Mounting Brackets Allows the inverter to be easily mounted. |
|
| PART NO. |
IM2000-24 |
| INPUT |
24V DC, 120A Max |
| OUTPUT |
230/240V AC 50Hz (Modified Sine Wave) |
| OUTPUT POWER |
2000W Continuous (4000W Peak) |
| IDEAL BATTERY SIZE |
50-200Ah |
| MINIMUM BATTERY SIZE |
50Ah, 400CCA
|
| RUN TIME WITH 2000W ON 50Ah BATTERY |
5 min |
| RUN TIME WITH 100W GLOBE ON 50Ah BATTERY |
7 hours
|
| APPROVALS |
Electrical Safety, EMC |
| IWK3 |
3m, 32mm2 (2 B&S) wiring kit |
| IWK5 |
6m, 64mm2 (00 B&S) wiring kit |
| IFB-150 |
Fuse box with 150A ANL fuse |
| IF-150 |
150A ANL fuse |
|
|

|
IM4000-24
|
 |
| 4000 Watt 24V Inverter |
|
|
Ideal for situations where the demand for 240V power is constant. Perfect for work trucks where 240V appliances are required to meet OH&S requirements. |
|
|
Efficient 24V Power Conversion The use of a 24V system allows more efficient production of power due to the reduced current. |
Peak Power Technology Heavy duty MOSFET transistors and a high output transformer allow the inverter to power maximum loads from start up. |
Superior Noise Free Filtering All Projecta inverters have EMC filtering and large electrolytic capacitors for smoother power delivery so your TV, radio, DVD, computers, etc, run as though they are on mains power. |
Twin 240V Power Outlets Any combination of sockets can be used, provided the combined load does not exceed the inverter's rating. |
Low Battery Voltage Protection To protect your battery from permanent damage caused by a deep discharge, the IM4000-24 has a low battery warning buzzer and shut off. |
Thermostatically Controlled Cooling Fan A built in cooling fan ensures that the inverter continues to provide reliable power for longer periods when under heavy loads. |
Internally Bonded Earth System All Projecta inverters have an internally bonded earth system. This ensures that in the event of a 240V appliance failing, the inverter will immediately shut down, preventing any chance of electrocution. |
Mounting Brackets Allows the inverter to be easily mounted. |
|
| PART NO. |
IM4000-24 |
| INPUT |
24V DC, 240A Max |
| OUTPUT |
230/240V AC 50Hz (Modified Sine Wave) |
| OUTPUT POWER |
4000W Continuous (8000W Peak) |
| IDEAL BATTERY SIZE |
75-300Ah |
| MINIMUM BATTERY SIZE |
75Ah, 550CCA
|
| RUN TIME WITH 150W ON 17Ah BATTERY |
5 min |
| RUN TIME WITH 100W GLOBE ON 17Ah BATTERY |
12 hours
|
| APPROVALS |
Electrical Safety, EMC |
| IWK7 |
3m, 64mm2 (00 B&S) wiring kit |
| IFB-250 |
Fuse box with 250A ANL fuse |
| IF-250 |
250A ANL fuse |
|
|
|