Contact Us

Use the form on the right to contact us.

You can edit the text in this area, and change where the contact form on the right submits to, by entering edit mode using the modes on the bottom right. 

           

123 Street Avenue, City Town, 99999

(123) 555-6789

email@address.com

 

You can set your address, phone number, email and site description in the settings tab.
Link to read me page with more information.

12V 120W ‘Power Can’ Modified Sine Wave Inverter

Inverters

12V 120W ‘Power Can’ Modified Sine Wave Inverter

im120.tag.0.png
IM120-2.png
IM120-3.png
IM120-4.png
IM120-5.png
IM120-6.png
IM120-Applications-Guide.png
Modified-Sine-Wave-logo.png
im120.tag.0.png
IM120-2.png
IM120-3.png
IM120-4.png
IM120-5.png
IM120-6.png
IM120-Applications-Guide.png
Modified-Sine-Wave-logo.png

12V 120W ‘Power Can’ Modified Sine Wave Inverter

0.00

PART NO IM120

Can sized inverter ideal for powering electrical equipment including iPads, mobile phones etc. and fits neatly into most vehicle cup holders.

FEATURES

2 Amp USB port
Ideal for charging devices including MP3s, iPods, iPads and smart phones

'Can' shape design
Conveniently stows in cup holder of vehicle for ease of use

Cigarette lighter plug
Fuse protected heat resistant plug with high current transfer tip and 0.6m lead

L.E.D indicators
Power and fault lights with audible alarm if problem is detected

Efficient design
Internal heat sink with vented base for effective heat dissipation

> Range features and application guide

Add To Cart
SPECIFICATIONS

PART NO

IM120

INPUT

12V DC, 20A Max

NO LOAD CURRENT DRAW

0.3A

OUTPUT

230/240VAC, 50Hz (Modified Sine)

OUTPUT POWER

120W Continuous (300W Peak)

INVERTER CLASSIFICATION

Equipotentially Bonded (EPB)

EFFICIENCY

85%

LOW BATTERY ALARM

10.0 Volt (±0.5V)

SHUTDOWN

10.0 Volt (±0.5V)

COOLING FAN

No

THERMAL SHUTDOWN

65°C (±5°C)

FUSE

1 x 20A

IDEAL BATTERY SIZE

50–70Ah

MINIMUM BATTERY SIZE

17Ah, 100CCA

RUN TIME WITH 120W ON 17Ah BATTERY

40 minutes

RUN TIME WITH 100W GLOBE ON 17Ah BATTERY

80 minutes

WARNING ALARM

LED & Audible alarm indicates a fault

APPROVALS

Electrical Safety, EMC

INSTRUCTION MANUAL

> Download PDF