Contact Us

Use the form on the right to contact us.

You can edit the text in this area, and change where the contact form on the right submits to, by entering edit mode using the modes on the bottom right. 

           

123 Street Avenue, City Town, 99999

(123) 555-6789

email@address.com

 

You can set your address, phone number, email and site description in the settings tab.
Link to read me page with more information.

24V 2000W Modified Sine Wave Inverter

Inverters

24V 2000W Modified Sine Wave Inverter

im2000-24v.tag.0.png
IM2000-24-2.png
IM2000-24-3.png
IM2000-24-4.png
IM2000-24-5.png
IM2000-24-6.png
IM2000-24-Application-Guide.png
IM2000-24-dim-diag.png
Modified-Sine-Wave-logo.png
im2000-24v.tag.0.png
IM2000-24-2.png
IM2000-24-3.png
IM2000-24-4.png
IM2000-24-5.png
IM2000-24-6.png
IM2000-24-Application-Guide.png
IM2000-24-dim-diag.png
Modified-Sine-Wave-logo.png

24V 2000W Modified Sine Wave Inverter

0.00

PART NO IM2000-24

The perfect inverter to run the comforts of home when on long
and demanding road trips.

FEATURES

Battery cable
1100mm 25mm2 battery cable

Twin power sockets
AS/NZS approved 240V sockets. Inverter designed to Australian standard AS4763

L.E.D indicators
Power and fault lights with audible alarm if problem is detected

Efficient design
Temperature controlled automatic cooling fan

Mounting flange
Convenient and robust mounting points

> Range features and application guide

Add To Cart
SPECIFICATIONS

PART NO

IM2000-24

INPUT

24VDC, 120A Max

NO LOAD CURRENT DRAW

0.6A

OUTPUT

230/240VAC, 50Hz (Modified Sine)

OUTPUT POWER

2000W Continuous (4000W Peak)

INVERTER CLASSIFICATION

Equipotentially Bonded (EPB)

EFFICIENCY

85–90%

LOW BATTERY ALARM

21.0 Volt

SHUTDOWN

20.0 Volt (±0.2V)

COOLING FAN

Automatic temperature controlled

THERMAL SHUTDOWN

65°C (±5°C)

FUSE

12 x 10A

IDEAL BATTERY SIZE

50–200Ah

MINIMUM BATTERY SIZE

50Ah, 400CCA

RUN TIME WITH 2000W ON 85Ah BATTERY

5 minutes

RUN TIME WITH 100W GLOBE ON 50Ah BATTERY

7 hours

WARNING ALARM

LED & Audible alarm indicates a fault

APPROVALS

Electrical Safety, EMC

INSTRUCTION MANUAL

> Download PDF